( Brand: Hamamatsu ), ( Manufacturer Part Number: HC142-02 ), ( Part Type: Module Cable Filter ), ( Country/region Of Manufacture: United States )
Experience the pinnacle of photomultiplier tube (PMT) technology with the Sony Icyt Modules HC142-02 kit, a meticulously crafted solution for your scientific imaging needs. This extensive kit, designed by Sony, includes all the essential components required for a seamless and efficient setup.
At the heart of the kit lies the Hamamatsu R6357 Photomultiplier Tube, a high-performance PMT that excels in sensitivity, speed, and stability. Its superior photon detection capabilities make it an ideal choice for various imaging applications, ranging from astronomy to medical research.
The kit also comes with a power supply unit specifically designed for the Sony Icyt Modules, ensuring optimal performance and reliability. This power supply unit offers adjustable voltage and current settings, allowing you to fine-tune the PMT performance according to your specific requirements.
The Sony Icyt Modules HC142-02 kit also includes an assortment of optical filters. These filters are essential for controlling and manipulating the light that enters the PMT, thereby enabling you to optimize the imaging results for your specific application. The kit includes a variety of filters, such as short-pass, long-pass, and band-pass filters, providing you with the flexibility to tailor your imaging setup to your needs.
Lastly, the Sony Icyt Modules HC142-02 kit is equipped with top-quality optical cables. These cables are designed to minimize signal loss and ensure the highest possible data transfer rates, contributing to the overall performance and efficiency of your imaging system.
In conclusion, the Sony Icyt Modules HC142-02 kit offers a comprehensive, high-performance solution for your scientific imaging needs. With its premium components, including the Hamamatsu R6357 PMT, power supply unit, optical filters, and optical cables, this kit is an excellent choice for researchers, astronomers, and anyone else seeking superior imaging performance.
The Sony ICHC142-02 Icyt Modules, comprising Hamamatsu R6357 PMTs, power supply, cables, and optical filters, are often used in scientific and research applications. Here's a list of pros and cons to help you make an informed decision:
Pros:1. High-quality components: Hamamatsu R6357 PMTs are known for their excellent photomultiplier tube (PMT) performance, making them suitable for various scientific applications.
2. Comprehensive kit: The kit includes all necessary components such as power supply, cables, and optical filters, making it convenient for users who need a complete setup.
3. Sony's reputation: Sony is a reputable brand in the industry, known for producing high-quality, reliable products.
4. Wide applicability: These modules can be used in a variety of scientific fields, including biology, chemistry, and physics, making them versatile for researchers.
Cons:1. High cost: The cost of this kit can be quite high, which may not be feasible for researchers or institutions with limited budgets.
2. Potential compatibility issues: Ensure that the kit is compatible with your existing equipment to avoid any potential issues.
3. Complex setup: Depending on the specific application, the setup process may require technical expertise and time.
4. Limited customization options: Since this is a pre-packaged kit, there may be limited options for customization to fit specific research needs.
In conclusion, the Sony ICHC142-02 Icyt Modules kit offers high-quality components, convenience, and versatility. However, the high cost, potential compatibility issues, complex setup, and limited customization options may be drawbacks for some users. If budget and compatibility are not major concerns, and the versatility and high-quality components are essential to your research, then this kit could be a recommended purchase. If budget is a concern, consider looking for alternatives or negotiating for a better price. Always ensure to thoroughly research and understand the specific requirements of your research project before making a purchase decision.
I tested the module control boards with power applied, all expected voltage s appeared on test pins. Units receive power from a main psu unit and output signal via SAM connectors 900nm. Buyer pays shipping, 40lbs from I did carefully open one of the pmt modules to identify which photo multiplier tube it used, is Hamamatsu R6357. Qty 4 laser input blocks.
I don't have the lasers FAQ system to see signal coming SAM connectors. All other 11 modules remain sealed. Consists of 4 pmt module boxes containing a total 12 Hamamatsu HC142-02 modules each.
Qty 12 SAM to cables for pmt signal output. Module 1:channel 1: 720nm bacchanal 2: 575nm 3: 670nm 4: 780nm peptics: mirror, 750lp, 703lp, channel 655nm 520bp 450nm 575bp 605nm 460bp 710nm 670bp optics: 625lp, 480lpmodule HQ 585 40 channel ET 625 30 optics: 645 Dix, t605 lox, RCMP, 650lpmodule 4:channel et535 50 channel 488nm BP 505sp, 550lp, rcpt 1 power supply unit, 12 outputs, 120v input cable included. Lot of components used pulled from decommissioned sony biotech icyt reflection flow centimeter fluorescence detection assembly.
Unknown lens calumniators on each. Each module contains a bank of optical filters mirrors arrayed to distribute the laser all PMS inside.
Qty 4 psu to pmt module power cables. Consequently, i'd call them partially tested, buyer beware.
Qty 4 pmt assembly modules all PMS are same model 12 Hamamatsu HC142-02, filter mirror combinations listed.